阳春力士乐驱动器运行显示F220代码维修|廉江力士乐驱动器维修
当时设备出现F220故障报警时操作人员肯定是非常着急的。尤其是出现不同语言的代码更加让人头疼。含义:Bleeder OvertemperatureShutdown放气器过热停机
Description:故障说明:
The regenerated energy from the mechanism of the machine viathe
motor has exceeded the power capability of the bleeder resistor.By
exceeding the maximum resistance energy, the drive willshutdown
according to the set error reaction. Thereby protecting thebleeder from
temperature damage.
通过电机已超过泄放电阻器的功率能力。通过超过大阻力能量,驱动器将关闭根据设定误差反应。从而保护泄放器免受温度损坏。
Cause:原因:
The reflected energy from the machine’s mechanism over the motoris
too large.电机上机器机构的反射能量为太大。
Remedy:解决方式:
With too much power ---> reduce the acceleration value
功率过大-->降低加速度值
With too much energy ---> reduce the velocity
能量过大--->降低速度
Check the drive installation.
检查驱动器安装。
May require installation of an additional bleeder module.
可能需要安装额外的放气模块。