冲版机ABB伺服驱动器维修-MotiFlex e180报警4018维修
ABB驱动器故障代码4018: Can't fit model to voltagelcurrent data(_eaCANNOT_FIT_RESISTANCE_MODEL)
4018不能拟合电压电流数据(_eaCANNOT_FIT_FIT_电阻模型)
During the Measure motor resistance and inductance test, agradually increasing voltage is applied to the motor and the
在测量电机电阻和电感的试验中,对电机施加一个逐渐增加的电压。
generated current is logged.The process is stopped when thedrive current reaches 80% of the specifed motor ratedcurrentvalue.The resulting voltage/current characteristic is usedto calculate the resistance of the windings and certain parametersofthe drive's power stage.Error 4018 will occur if there is notenough data in the voltage/current characteristic to performthecalculation.
当驱动电流达到指定电机额定电流值的80%时,该过程停止。由此产生的电压/电流特性用于计算绕组的电阻和驱动器功率级的某些参数。如果电压/电流特性中没有足够的数据来进行计算,则会出现错误4018。
The error can also occur because of a motor or wiring fault. Checkthat the motor is wired correctly and there are noshort-circuits.ldeally, remove AC power from the drive, unplug themotor power connector (X1), and use a test meter to checktheresistance across the UN, VW and WlU terminals of the cableconnector. The three resistance values should be the same andmatchthe catalog values specified for the motor.